PES POWER · Kazakhstan
FORTE EPOWER — 10–800 kVA
FORTE EPOWER — transformer-based online UPS from 10 to 800 kVA with an integrated output isolation transformer. Designed for industrial facilities and demanding power grids: high starting currents, nonlinear loads and interference.
They withstand a 150% overload for one minute. High-power models are available with a 12-pulse rectifier.
Common specifications
- 3/3 phases; output 380/400/415 V ±1%; PF 0.9; series efficiency up to 94%. Overload: 110% for 60 min, 125% for 10 min, 150% for 1 min. Transfer time: 0 ms; operating temperature: 0…+40 °C.
- RS232 and RS485 (MODBUS), EPO; dry contacts are optional for 10–160 kVA and standard for 200–800 kVA; SNMP card is optional. 6P and 12P identify 6-pulse and 12-pulse rectifier versions.
Models and specifications
| Model | Power kVA / kW | Online efficiency, up to % | Dimensions W × D × H, mm | Weight, kg | Batteries / DC bus |
|---|---|---|---|---|---|
| EPOWER GP3310 | 10 kVA / 9 kW | 88 | 350 × 650 × 1050 | 145 | 384 V DC (360–384 V) |
| EPOWER GP3320 | 20 kVA / 18 kW | 89 | 350 × 650 × 1050 | 165 | 384 V DC (360–384 V) |
| EPOWER GP3330 | 30 kVA / 27 kW | 89 | 350 × 650 × 1050 | 204 | 384 V DC (360–384 V) |
| EPOWER GP3340 | 40 kVA / 36 kW | 90 | 430 × 830 × 1100 | 255 | 384 V DC (360–384 V) |
| EPOWER GP3360 | 60 kVA / 54 kW | 90 | 430 × 830 × 1100 | 320 | 384 V DC (360–384 V) |
| EPOWER GP3380 | 80 kVA / 72 kW | 90,5 | 720 × 690 × 1400 | 450 | 384 V DC (360–384 V) |
| EPOWER GP33100-6P | 100 kVA / 90 kW | 92 | 720 × 690 × 1400 | 556 | 384 V DC (360–384 V) |
| EPOWER GP33100-12P | 100 kVA / 90 kW | 92 | 1515 × 830 × 1600 | 1300 | 384 V DC (360–384 V) |
| EPOWER GP33120-6P | 120 kVA / 108 kW | 92 | 890 × 790 × 1600 | 693 | 384 V DC (360–384 V) |
| EPOWER GP33120-12P | 120 kVA / 108 kW | 92 | 1515 × 830 × 1600 | 1450 | 384 V DC (360–384 V) |
| EPOWER GP33160-6P | 160 kVA / 144 kW | 92,5 | 890 × 790 × 1600 | 780 | 384 V DC (360–384 V) |
| EPOWER GP33160-12P | 160 kVA / 144 kW | 92,5 | 1400 × 1000 × 1900 | 1645 | 384 V DC (360–384 V) |
| EPOWER GP33200-6P | 200 kVA / 180 kW | 92,5 | 1200 × 800 × 1600 | 1030 | 384 V DC (360–408 V) |
| EPOWER GP33200-12P | 200 kVA / 180 kW | 92,5 | 1400 × 1000 × 1900 | 1715 | 384 V DC (360–408 V) |
| EPOWER GP33300-6P | 300 kVA / 270 kW | 93 | 1400 × 1000 × 1900 | 1560 | 384 V DC (360–408 V) |
| EPOWER GP33300-12P | 300 kVA / 270 kW | 93 | 1640 × 1000 × 1900 | 2395 | 384 V DC (360–408 V) |
| EPOWER GP33400-6P | 400 kVA / 360 kW | 93 | 1400 × 1000 × 1900 | 1640 | 384 V DC (360–408 V) |
| EPOWER GP33400-12P | 400 kVA / 360 kW | 93 | 1640 × 1000 × 1900 | 2510 | 384 V DC (360–408 V) |
| EPOWER GP33500-12P | 500 kVA / 450 kW | 93,5 | 2580 × 1000 × 1900 | 3510 | 480 V DC |
| EPOWER GP33600-12P | 600 kVA / 540 kW | 93,5 | 2800 × 1040 × 1900 | 3950 | 480 V DC |
| EPOWER GP33800-12P | 800 kVA / 720 kW | 94 | 3280 × 1040 × 1900 | 4950 | 600 V DC |
How EPOWER differs from GP33
EPOWER is a transformer-based industrial UPS with an output power factor of 0.9 and high overload capability. GP33 is a transformerless UPS with smaller dimensions and weight, higher efficiency and a power factor up to 1.0.
Model codes are similar, so specify the series name when ordering.
Supply and service
FORTE Green Power UPS are manufactured at KSTAR. Display menus and documentation are available in Russian and Kazakh.
Certificates and authorizationRequest a quotation · Runtime calculator
Frequently asked questions
How do I order?
Send PES POWER your load, required runtime, phases and installation city. Price and lead time are confirmed in the quotation.
Can runtime be determined from kVA alone?
No. Active load, battery configuration and discharge data are required.
The calculator provides a preliminary estimate.
Is service available in Kazakhstan?
PES POWER provides installation and service, with offices in Astana and Almaty and a warehouse in Almaty. The scope is agreed separately.
Equipment and solutions
Floor-standing online UPS, 1–20 kVA: single-phase 1–10 kVA and 10–20 kVA models with three-phase input.
Rack-mounted online UPS, 6–10 kVA, with 2U/3U/4U height depending on the version, for server cabinets.
Three-phase online UPS, 10–40 kVA, for offices, healthcare and server rooms.
Three-phase online UPS, 60–200 kVA, for large facilities and industrial sites.
Modular UPS up to 1250 kVA with 50, 100 and 125 kVA modules and N+1 redundancy for data centers.
Three-phase UPS, 10–20 kVA, with a 3U height for rack or floor installation.
VRLA batteries for UPS and backup power, with runtime calculations.
PES POWER: supply, installation and service of uninterruptible power systems in Kazakhstan since 2013.
Our own FORTE Green Power UPS and FORTE Battery Systems battery brands: who manufactures them and how they differ.
Articles on UPS selection, runtime calculations and battery service life.
Modular UPS with N+1 redundancy, batteries, generators and cooling.
Uninterruptible power for operating theatres, intensive care units, CT and MRI.
Power for lifts, escalators, security systems and server rooms.
Uninterruptible power for warehouses and distribution centers: conveyors, sorting, server rooms and record-keeping systems.
Protection for control systems and process lines against shutdowns.
diagnostics and battery replacement in UPS from any manufacturer.
scheduled maintenance, repairs and service contracts.
Wokang and Silico generators in open, enclosed and containerized configurations.
single-phase and three-phase, from 3.5 to 1200 kVA.
turnkey KSTAR cabinet, modular and containerized data centers.
PES POWER projects completed in Kazakhstan.